Sterile Packaging Validation Kit | ISO 11607-1 and -2
18 procedures, forms and lists to validate the packaging of terminally sterilized medical devices to ISO 11607-1 and ISO 11607-2, each with Amendment 1:2023. It covers the packaging system and the sealing process from design inputs to the final validation report, plus routine lot testing and revalidation decisions.
Quick facts
Product: Sterile Packaging Validation Kit
Written to meet: ISO 11607-1:2019 + Amd 1:2023 and ISO 11607-2:2019 + Amd 1:2023, with package testing to ASTM F88/F88M-23, ASTM F1929-23 and ASTM F1886/F1886M-25
For: medical device manufacturers, contract packagers and contract manufacturers that seal, form or assemble sterile barrier systems
Contents: 18 documents, including a packaging validation master plan, a sealer installation qualification protocol, a test method validation procedure and an ISO 11607 requirements matrix
Format: editable Microsoft Word and Excel files with PDF copies, in two editions (ISO 13485 and dual-standard procedure numbers), digital download
Price: $495 for a single-site license; $1,485 for a consultant license to use with clients
ISO 11607 asks for much more than sealer OQ and PQ. The packaging system needs a risk management process under the new Annex F of Amendment 1:2023, qualified materials with a proven microbial barrier, a usability evaluation for aseptic presentation, distribution performance testing, stability testing, validated test methods, and a recorded decision every time something changes. This kit gives you the procedures and records for all of it.
Packaging System Design and Validation Procedure (SOP 7-101-PKG) with the Packaging Validation Master Plan (FORM 0101-PKG) and the Packaging Validation Summary Report (FORM 0111-PKG): the master procedure, from design inputs to formal approval of the validation.
Packaging Risk Management Plan and Assessment (FORM 0102-PKG): microbial contamination, chemical contamination, adverse conditions and misleading information, with risk control in the order the 2023 amendments require.
Sterile Barrier Material Qualification Procedure (SOP 7-102-PKG) with the qualification record (FORM 0104-PKG): pouches, lidding, trays, wraps and labels, including microbial barrier data (ASTM F1608) and sterilization compatibility.
Packaging Process Validation and Control Procedure (SOP 7-103-PKG) with the Sealer Installation Qualification Protocol and Report (FORM 0105-PKG): IQ, OQ and PQ to ISO 11607-2, routine monitoring and process revalidation.
Package Test Method Validation Procedure (SOP 7-104-PKG) with its record (FORM 0108-PKG): repeatability, reproducibility and sensitivity for seal strength, dye penetration and visual inspection.
Routine Seal Strength and Package Integrity Testing Procedure (SOP 8-101-PKG) with the lot test record (FORM 0109-PKG): sampling, testing, failures and trends in production.
Usability Evaluation for Aseptic Presentation (FORM 0106-PKG), Packaging System Performance Test Protocol and Report (FORM 0107-PKG), Packaging Family and Worst-Case Rationale (FORM 0103-PKG) and Packaging Change and Revalidation Assessment (FORM 0110-PKG).
ISO 11607 Requirements Matrix (LIST 0101-PKG) and the Sterile Packaging Validation Kit Guide (GUIDE-PKG), with the order of work and a cross-reference to your own procedures.
Who it is for
Device manufacturers and contract packagers validating a new sterile package, closing ISO 11607 gaps found in an audit, or bringing existing packaging up to the 2023 amendments.
What you receive
An instant download of one zip file with a READ ME and two editions of the kit with the same content: one cites the procedure numbers of the ISO 13485 Manufacturing Plus system (for example SOP 7-012), the other the dual-standard system (for example SOP 7-012-C). Each edition has 1 guide, 1 requirements matrix, 5 procedures and 11 forms as editable Microsoft Word and Excel files, with a PDF copy of each.
Works with your quality system
The kit plugs into the MDSAP-Ready ISO 13485 QMS Manufacturing Plus and MDSAP-Ready QMS Manufacturing Plus systems. If you use a different system, the guide's cross-reference table has a column for your own procedure numbers.
For the sealer OQ and PQ test work, use the Bar Sealer, Tray Sealer or 4-Side Seal Pouch qualification protocols, which start where this kit's sealer IQ ends. For aging, use the Accelerated Aging Study Protocol; for the effect of a packaging change on a validated EO cycle, the Ethylene Oxide Product Adoption Protocol.
Related guides
ISO 11607 Packaging Validation: What the Standard and the 2023 Amendments Require
Sealer IQ, OQ and PQ Under ISO 11607-2: Validating the Sealing Process
Seal Strength, Dye Penetration or Visual Inspection: Choosing Package Tests
Not sure this is the right package? Take the free QMS gap check: answer about 20 questions and see your gaps by clause, the procedures that close each one, and whether a complete system or individual procedures costs less.
Keep your system current: the A.P. Lyon Update Service
Standards and regulations change. With the Update Service, you don't have to track those changes yourself. Every quarter, subscribers get a standards update bulletin and any revised documents for their system, posted to a subscriber-only Update Library on this site. $149 per year per system, or $449 per year for consultants. Renews yearly; cancel anytime. See the plans and add one to your cart