Biological Evaluation Kit | ISO 10993-1:2025
18 procedures, forms and lists that take a medical device step by step from "what touches the patient" to an approved biological evaluation report under ISO 10993-1:2025, with chemical characterization, toxicological risk assessment, test requests and change control.
Quick facts
Product: Biological Evaluation Kit
Written to meet: ISO 10993-1:2025, ISO 10993-17:2023 + Amd 1:2025, ISO 10993-18:2020 + Amd 1:2022, ISO 10993-12:2021 + Amd 1:2025, ISO/TS 21726:2019, ISO 10993-5:2009, ISO 10993-10:2021 and ISO 10993-23:2021
For: medical device manufacturers, design firms and contract manufacturers that must show the biological safety of a device that touches the body
Contents: 18 documents, including a biological evaluation plan and report, a chemical characterization protocol, an Excel toxicological risk assessment calculator and an ISO 10993 requirements matrix
Format: editable Microsoft Word and Excel files with PDF copies, in two editions (ISO 13485 and dual-standard procedure numbers), digital download
Price: $595 for a single-site license; $1,785 for a consultant license to use with clients
ISO 10993-1:2025 places biological evaluation inside risk management: you plan, set acceptance criteria, gather and gap-check existing data, characterize the chemistry, assess toxicological risk, and test only what is still open. This kit turns that into a course of action. Every procedure step names who does it, which form to fill in and where to go next, with clause references kept in a separate column.
Biological Evaluation Planning and Reporting Procedure (SOP 7-101-BIO) with the Device Description and Body Contact Categorization (FORM 0101-BIO), Existing Data and Clinical Use History Review (FORM 0102-BIO), Biological Evaluation Plan (FORM 0103-BIO) and Biological Evaluation Report (FORM 0110-BIO): the master route, from categorizing contact to an approved report.
Chemical Characterization and Toxicological Risk Assessment Procedure (SOP 7-102-BIO) with the Chemical Characterization Study Protocol (FORM 0104-BIO) and Results Review (FORM 0105-BIO): extraction approach, analytical evaluation threshold and constituent review to ISO 10993-18.
Toxicological Risk Assessment Record (FORM 0106-BIO): an Excel workbook that calculates worst-case exposure and the margin of safety for each constituent, applies the threshold of toxicological concern, and combines margins for constituents that affect the same organ.
Biological Test Sample Preparation and Laboratory Management Procedure (SOP 7-103-BIO) with the Test Sample Preparation Record (FORM 0107-BIO), Test Request and Laboratory Agreement (FORM 0108-BIO) and Test Report Review (FORM 0109-BIO): cytotoxicity, sensitization and irritation requests, extraction conditions and what to do with a failed result.
Biological Re-Evaluation and Change Assessment Procedure (SOP 7-104-BIO) with the Biological Impact Assessment for Changes (FORM 0111-BIO) and Periodic Review (FORM 0112-BIO): change screening, complaints and devices evaluated under an earlier edition.
Biological Evaluation Requirements Matrix (LIST 0101-BIO) and the Biological Evaluation Kit Guide (GUIDE-BIO), with an 8-stage road map, a worked example and a cross-reference to your own procedures.
Who it is for
Device makers bringing biological evaluations up to ISO 10993-1:2025, preparing a new device for submission, or assessing a material or supplier change.
What you receive
An instant download of one zip file with a READ ME and two editions of the kit with the same content: one cites the procedure numbers of the ISO 13485 Manufacturing Plus system (for example SOP 7-034), the other the dual-standard system (for example SOP 7-034-C). Each edition has 1 guide, 1 requirements matrix, 4 procedures and 12 forms as editable Microsoft Word and Excel files, with a PDF copy of each.
Works with your quality system
The kit puts into action the Biocompatibility and Toxicity Testing Procedure (SOP 7-034) of the MDSAP-Ready ISO 13485 QMS Manufacturing Plus and MDSAP-Ready QMS Manufacturing Plus systems. If you use a different system, the guide's cross-reference table has a column for your own procedure numbers.
A qualified toxicologist, in-house or contracted, must complete the toxicological risk assessment. The kit tells you what to ask for and how to check what comes back.
Related guides
Biological Evaluation Plan and Report Under ISO 10993-1:2025: A Step-by-Step Route
Toxicological Risk Assessment Under ISO 10993-17: TTC, Tolerable Intake and Margin of Safety
Chemical Characterization Under ISO 10993-18: Extraction, AET and What to Ask Your Lab
Not sure this is the right package? Take the free QMS gap check: answer about 20 questions and see your gaps by clause, the procedures that close each one, and whether a complete system or individual procedures costs less.
Keep your system current: the A.P. Lyon Update Service
Standards and regulations change. With the Update Service, you don't have to track those changes yourself. Every quarter, subscribers get a standards update bulletin and any revised documents for their system, posted to a subscriber-only Update Library on this site. $149 per year per system, or $449 per year for consultants. Renews yearly; cancel anytime. See the plans and add one to your cart
