Most findings at a clinical investigation site are not about the science. They are about the records: a coordinator who took consent before being added to the delegation log, a subject who dropped out with no reason recorded, three devices that cannot be traced from shipment to disposal, a deviation that was fixed but never written down. Each one weakens the data and raises a question about whether subjects were protected. The fix is not more paperwork. It is a small set of logs that are started at the right moment and kept current by the people who do the work.


This guide sets out a practical route for the site records of a medical device clinical investigation, from site initiation to close-out. The requirements are summarized in our own words from ISO 14155:2026 and, for U.S. investigations, 21 CFR Part 812. Check the standard and the official text at www.ecfr.gov before relying on them.


What the standard and the regulation require


ISO 14155:2026 sets the site records across several clauses. Clause 7.2 and clause 9.2.1 f) require a log of the site team, started at initiation. Clause 7.5.2 requires a log of every enrolled subject. Clause 7.9 requires device accountability. Clause 10.6 makes the principal investigator responsible for source documents, accountability records, deviations and record retention. Clause 8.3 sets out what routine close-out must confirm, and clause 8.6 with Annex E covers the essential documents that make up the site and sponsor files.


In the United States, 21 CFR 812.140(a) lists the records each investigator keeps: correspondence, device receipt, use and disposition records, each subject's case history and device exposure, and the protocol with the dates and reasons for each deviation. 21 CFR 812.100 and 812.110 require the investigator to control the devices under investigation and to supply them to no unauthorized person.


Step 1: start the delegation log at initiation


The site team log is started at the site initiation visit, not when the first subject is screened. ISO 14155:2026 clauses 7.2 and 9.2.1 f) require it to identify, for the principal investigator and each site team member, the name, initials, signature, function and the authorizations delegated to them.


Write the authorizations as tasks, not job titles. "Study coordinator" tells a monitor nothing. "Obtains informed consent, completes CRFs, dispenses devices" tells them exactly what to check. A useful log has one column for each task the CIP assigns: consent, eligibility assessment, device use, adverse event assessment, CRF entry and sign-off, device dispensing and return. The principal investigator signs and dates each line to show the delegation is theirs.


Keep a start date and an end date for every person. When someone leaves, the line is closed, not deleted, so that the log still shows who was authorized on any given date.


Step 2: train before anyone starts, and add them to the log


ISO 14155:2026 clause 7.6 says new site team members start only after documented training on the investigation requirements, and their details are then added to the log. The ethics committee may also need to be told or to approve, depending on its rules.


The order matters. Training first, log entry second, work third. A monitor comparing the log with the source documents will look for any task done before the person's start date. Clauses 9.2.1 g) and h) set out what the training covers: the investigational device, device accountability, the investigator's brochure, the CIP, the CRFs, the informed consent form and process, and the applicable regulations and sponsor procedures. File each training record where the monitor can find it, and refer to it from the log line.


Step 3: log every subject from first contact to last visit


Clause 7.5.2 requires each site to keep a log of all enrolled subjects. Each subject gets an identification code linked to their name, alternative identification or contact information. Depending on the design, the site can also keep a log of everyone pre-screened for possible enrollment. A screening log is worth keeping in most investigations: it shows the ethics committee and the sponsor whether the eligibility criteria are working, and it explains the gap between the subjects seen and the subjects enrolled.


For each subject, record the screening date, the date consent was signed, the eligibility decision and who made it, the enrollment date and the code. The consent date must come before the date of any investigation procedure. Clause 9.2.4.5 asks the monitor to verify exactly that, so make it easy to see on one line.


Eligibility criteria are not negotiable. Clause 5.6.4 b) says deviations from the eligibility criteria are not permitted. A subject who does not meet them is not enrolled, however close the miss. If the criteria are wrong, the CIP is amended.


Step 4: account for every subject, including the ones who leave


Clause 7.10 requires all enrolled subjects to be accounted for and documented, including those withdrawn or lost to follow-up, with the reason for discontinuation recorded if it is known. With the subject's permission, follow-up data on their status may be collected and is then included in the clinical investigation report.


Add three columns to the subject log for this: status (active, completed, withdrawn, lost to follow-up), the date, and the reason. "Lost to follow-up" should record what was done to reach the subject, such as the number and dates of contact attempts. At close-out, every enrolled subject must have a final status. A subject who simply disappears from the log is a finding.


Step 5: trace every device from receipt to return


Clause 7.9 requires access to investigational devices to be controlled and the devices to be used only in the investigation, as the CIP describes. The principal investigator or a designee records:


  • who received, used, returned or disposed of each device;

  • the date of receipt, the identification (batch, serial number or unique code) and the quantity;

  • the expiry date;

  • the dates of use and the subject identification;

  • the date returned or explanted;

  • the date any unused, expired or malfunctioning device was returned;

  • disposal according to the sponsor's instructions.


21 CFR 812.140(a) asks for the same trail: type and quantity, dates, batch, the persons involved and returns. Keep it as one running log for each site, with one line for each device or batch movement. A balance column (received, minus used, minus returned, minus disposed) shows at a glance whether anything is missing. When the balance does not match the stock on the shelf, the investigation into why starts that day.


Store the devices where only authorized site team members can reach them. A device that reaches anyone else breaks both clause 7.9 and 21 CFR 812.110.


Step 6: record every deviation, and decide what it needs


ISO 14155:2026 clause 3.18 defines a deviation as any intentional or unintentional failure to follow the CIP. A missed visit window, a test done on the wrong day and a CRF completed late are all deviations. Clause 10.6 requires the principal investigator to document and explain every one.


A deviation log needs, for each entry: the date it occurred and the date it was found, the subject, what happened, why, whether it affected subjects' rights, safety or well-being or the scientific integrity of the investigation, who was told and when, and the action taken. Deviations that affect subjects or scientific integrity go to the ethics committee as required.


Emergency deviations are a separate case. A deviation made to protect a subject in an emergency may go ahead without prior approval, but it is documented and reported to the sponsor and the ethics committee as soon as possible. In the United States, 21 CFR 812.35(a) and 812.150(a) set the limit for reporting an emergency deviation at 5 working days.


Nobody at the site changes the CIP. Clause 10.6 says the principal investigator makes no change without the agreement of the sponsor, the ethics committee and the regulatory authority as required. In the United States, 21 CFR 812.35(a) requires changes to the investigational plan to be approved before they are made, with the listed exceptions.


Step 7: look for patterns, not just entries


One late visit is a deviation. The same late visit at the same site every month is a system problem. Clause 8.2.1 says serious or repeated deviations lead the sponsor to consider suspending or terminating the site or the investigator. Clause 10.6 also asks the principal investigator to determine causes and implement corrective and preventive action for significant non-compliance.


Sort the deviation log by type and by site each time the monitor reviews it. Where the same type keeps returning, open a CAPA and look for the cause: an unclear visit schedule, a CRF that does not match the CIP, too few staff on the team. A log that is only ever read one line at a time will never show the pattern.


Step 8: close out each site with a checklist


Close-out is where missing records come to light, so plan it as a checklist rather than a meeting. Clause 8.3 requires the routine close-out at each site to confirm:


  • all essential documents are complete and current;

  • all CRFs are completed and all queries resolved;

  • the status of every ongoing adverse event is documented;

  • archiving and retention are arranged;

  • the disposition of investigational devices, remaining samples and other materials is documented.


Clause 9.2.4.6 makes the monitor responsible for these close-out activities. The ethics committee, the regulatory authority where required, and the public database are notified that the investigation is complete. In the United States, 21 CFR 812.150(a) requires the investigator to send a final report within 3 months after the study, or their part of it, ends.


Record the close-out as one signed report for each site, with a line for each item, its status and the evidence. Any open item gets an owner and a date. A device balance that is not zero, a subject with no final status, or a query still open means the site is not closed.


If the investigation is suspended or terminated early, clause 8.2 says the routine close-out activities are still carried out. Early termination is not a shortcut past close-out.


Step 9: keep the essential documents where you can find them


Clause 8.6 requires the sponsor and the principal investigator to maintain the investigation documents, to prevent accidental or premature destruction, and to document any transfer of custody. Annex E of ISO 14155:2026 is informative. It lists the essential documents expected in the site and sponsor files before, during and after the investigation, and it recommends recording where each one is kept, in a storage system that provides identification, version history, search and retrieval.


Use Annex E as a checklist from the start, not only at close-out. Each document gets a line: whether it applies, the version, where it is filed, and the date it was last checked. At close-out, the same checklist shows the file is complete.


For retention, your quality system sets the floor. ISO 13485:2016 clause 4.2.5 requires records to be kept for at least the lifetime of the device as the organization defines it, or as regulations require, and not less than two years from release. 21 CFR 812.140(d) keeps Part 812 records for 2 years after the later of the end of the investigation or the date they are no longer needed to support a marketing application, and 812.140(e) requires FDA to be notified within 10 working days of any transfer of custody.


Common site record mistakes


  • Delegation log started late. Tasks done before a person's start date cannot be shown to be authorized.

  • Job titles instead of tasks. The monitor cannot tell who may take consent.

  • No screening log. Nobody can explain why enrollment is slow.

  • Subjects who simply stop appearing. Withdrawals and losses to follow-up have no status, date or reason.

  • Device counts that do not balance. A missing device is found at close-out instead of the week it went missing.

  • Deviations fixed but not recorded. The site corrects the problem and leaves no trail.

  • No trend review of deviations. The same deviation is logged every month and nothing changes.

  • Close-out by memory. Without a checklist, open queries and undocumented devices are left behind.


Putting it into practice


The Clinical Investigation Conduct Forms Kit turns this route into numbered steps. FORM 0102-CIF is the site delegation and signature log, with a column for each delegated task and start and end dates. FORM 0103-CIF holds the subject screening and enrollment log and the device accountability log. FORM 0106-CIF is the CIP deviation log, with impact, emergency and reporting columns. FORM 0107-CIF is the site close-out report, and FORM 0108-CIF is the essential documents checklist built on Annex E. It comes in ISO 13485 and dual-standard editions and builds on the A.P. Lyon Clinical Investigation Procedure (SOP 7-039 or SOP 7-039-C). For how the monitor checks these records, see How to Write a Risk-Based Monitoring Plan Under ISO 14155:2026. For the safety records that sit beside them, see Adverse Event and Device Deficiency Reporting in Device Clinical Investigations.


Frequently asked questions


Does ISO 14155 require a screening log?


Not always. Clause 7.5.2 requires a log of all enrolled subjects, and says a log of everyone pre-screened can also be kept, depending on the design. Most sponsors ask for one because it shows whether the eligibility criteria and recruitment are working.


Can a site enroll a subject who narrowly misses an eligibility criterion?


No. ISO 14155:2026 clause 5.6.4 b) does not permit deviations from the eligibility criteria. If the criteria need to change, the CIP is amended.


Is a missed visit window a deviation?


Yes. Any intentional or unintentional failure to follow the CIP is a deviation under clause 3.18. It is recorded and explained, and the CIP and the ethics committee's rules decide whether it must be reported.


Who performs the site close-out?


ISO 14155:2026 clause 9.2.4.6 gives the close-out activities to the monitor. The sponsor makes sure close-out is properly conducted under clause 9.2.6, and the principal investigator supports it and keeps the site records.


Building a complete quality system? Build Your QMS lets you choose ISO 13485 + FDA QMSR, Dual-Standard or ISO 9001:2026 procedures in one place, and applies volume discounts automatically: 20% off 5–9 procedures, 35% off 10–19, 50% off 20–39 and 60% off 40 or more.


Not sure where your quality system stands? Take the free QMS gap check: about 20 questions, an instant report of your gaps by clause, and the procedures that close each one.


Just getting started? The free Startup Quality Plan shows which procedures you need now, which can wait, and how long they take to put in place.