Radiation Sterilization Validation Kit | ISO 11137
15 procedures, forms and lists that take a medical device step by step from "we need a validated radiation process" to an approved validation report, routine release and quarterly dose audits under ISO 11137, for gamma, electron beam or X-ray, with bioburden and sterility testing, the maximum acceptable dose, VDmax25 or Method 1 dose setting, dose mapping and change review.
Quick facts
Product: Radiation Sterilization Validation Kit
Written to meet: ISO 11137-1:2025, ISO 11137-2:2013 + Amd 1:2022, ISO 11137-3:2017, ISO 11737-1:2018 + Amd 1:2021 and ISO 11737-2:2019
For: medical device manufacturers that sterilize with gamma, electron beam or X-ray, usually through a contract irradiator and a contract laboratory
Contents: 15 documents, including a validation master plan, a maximum acceptable dose study, a VDmax25 / Method 1 dose setting record, a dose mapping protocol and report, a dose audit record and an ISO 11137 requirements matrix
Format: editable Microsoft Word and Excel files with PDF copies, in two editions (ISO 13485 and dual-standard procedure numbers), digital download
Price: $595 for a single-site license; $1,785 for a consultant license to use with clients
ISO 11137 asks you to define the product family, know the bioburden, accept the irradiator's qualification and dosimetry, find the highest dose the product can take, establish the sterilization dose, map the dose in your load, write a process specification, and then prove the dose still works with regular dose audits. This kit turns that into a course of action. Every procedure step names who does it, which form to fill in and where to go next, with clause references kept in a separate column.
Radiation Validation Planning and Execution Procedure (SOP 7-101-RAD) with the Product Family and Test Sample Record (FORM 0101-RAD) and Radiation Validation Master Plan (FORM 0102-RAD): the master route, from product family and processing category to an approved report.
Maximum Acceptable Dose Study (FORM 0105-RAD) and Dose Setting Protocol and Record (FORM 0106-RAD): product and package tests after irradiation and aging, and VDmax25 or Method 1 dose setting with sample selection, the verification dose experiment and how to read the result.
Dose Mapping Protocol and Report (FORM 0108-RAD): review of the irradiator's IQ, OQ and dosimetry evidence, product dose mapping, minimum and maximum dose zones, and the routine monitoring dose range with measurement uncertainty.
Bioburden and Sterility Testing Procedure (SOP 8-101-RAD) with the Bioburden Method Validation Record (FORM 0103-RAD), Bioburden Test Record and Trend (FORM 0104-RAD) and Sterility Test Record (FORM 0107-RAD): method validation, correction factors, alert and action levels and quarterly trending.
Dose Audit, Routine Control and Release Procedure (SOP 7-102-RAD) with the Validation Report and Release Specification (FORM 0109-RAD) and Dose Audit Record and Change Review (FORM 0110-RAD): run control and release, quarterly dose audits, failed audits, lengthening the audit interval, annual family review and change assessment.
Radiation Sterilization Requirements Matrix (LIST 0101-RAD) and the Radiation Sterilization Validation Kit Guide (GUIDE-RAD), with a 10-stage road map, a worked example and a cross-reference to your own procedures.
Who it is for
Device makers validating a new radiation process or product family, moving to electron beam or X-ray, or bringing their dose audits and older validations up to ISO 11137-1:2025.
What you receive
An instant download of one zip file with a READ ME and two editions of the kit with the same content: one cites the procedure numbers of the ISO 13485 Manufacturing Plus system (for example SOP 7-036), the other the dual-standard system (for example SOP 7-036-C). Each edition has 1 guide, 1 requirements matrix, 3 procedures and 10 forms as editable Microsoft Word and Excel files, with a PDF copy of each.
Works with your quality system
The kit puts into action the Gamma Irradiation Validation and Monitoring procedure (SOP 7-036) and the Sterile Load Preparation and Release procedure (SOP 7-023) of the MDSAP-Ready ISO 13485 QMS Manufacturing Plus and MDSAP-Ready QMS Manufacturing Plus systems. If you use a different system, the guide's cross-reference table has a column for your own procedure numbers.
Your irradiator runs the equipment, dosimetry and irradiation, and your contract laboratory runs the tests. The kit tells you what to ask each of them for and how to check what comes back.
Related guides
Radiation Sterilization Validation Under ISO 11137-1:2025: A Step-by-Step Route
VDmax25 Dose Substantiation and Dose Audits Under ISO 11137-2
Not sure this is the right package? Take the free QMS gap check: answer about 20 questions and see your gaps by clause, the procedures that close each one, and whether a complete system or individual procedures costs less.
Keep your system current: the A.P. Lyon Update Service
Standards and regulations change. With the Update Service, you don't have to track those changes yourself. Every quarter, subscribers get a standards update bulletin and any revised documents for their system, posted to a subscriber-only Update Library on this site. $149 per year per system, or $449 per year for consultants. Renews yearly; cancel anytime. See the plans and add one to your cart