EO Sterilization Validation Kit | ISO 11135
15 procedures, forms and lists that take a medical device step by step from "we need a validated ethylene oxide process" to an approved validation report and routine load release under ISO 11135, with bioburden and sterility testing, microbiological and physical PQ, EO residuals, requalification and change review.
Quick facts
Product: EO Sterilization Validation Kit
Written to meet: ISO 11135:2014 + Amd 1:2018, ISO 11737-1:2018 + Amd 1:2021, ISO 11737-2:2019 and AAMI TIR28:2016 (R2024)
For: medical device manufacturers that sterilize with ethylene oxide, usually through a contract sterilizer and a contract laboratory
Contents: 15 documents, including a validation master plan, microbiological and physical PQ protocols and reports, a validation report and an ISO 11135 requirements matrix
Format: editable Microsoft Word and Excel files with PDF copies, in two editions (ISO 13485 and dual-standard procedure numbers), digital download
Price: $595 for a single-site license; $1,785 for a consultant license to use with clients
ISO 11135 asks you to define the product and its hardest-to-sterilize location, plan the validation, know the bioburden, accept the sterilizer's IQ and OQ, prove lethality in a microbiological PQ, show the process is reproducible in a physical PQ, confirm the product and its residuals, and then keep the process validated. This kit turns that into a course of action. Every procedure step names who does it, which form to fill in and where to go next, with clause references kept in a separate column.
EO Validation Planning and Execution Procedure (SOP 7-101-EO) with the Product Family and Process Challenge Device Record (FORM 0101-EO), EO Validation Master Plan (FORM 0102-EO) and Sterilizer IQ and OQ Evidence Review (FORM 0105-EO): the master route, from product definition and PCD choice to an approved report.
Microbiological PQ Protocol and Report (FORM 0106-EO) and Physical PQ Protocol and Report (FORM 0108-EO): fractional and half cycles with PCDs, three consecutive full cycles with temperature and humidity sensors, and how to set routine limits from the data.
Product Qualification and EO Residuals Record (FORM 0109-EO): product and package function after worst-case exposure, biological safety, residual testing and the minimum aeration time.
Bioburden and Sterility Testing Procedure (SOP 8-101-EO) with the Bioburden Method Validation Record (FORM 0103-EO), Bioburden Test Record and Trend (FORM 0104-EO) and Sterility Test Record (FORM 0107-EO): method validation, correction factors, alert and action levels and quarterly trending.
EO Routine Control, Release and Requalification Procedure (SOP 7-102-EO) with the Validation Report, Requalification and Change Review (FORM 0110-EO): load release, failed loads, annual review, product adoption into a validated family and change assessment.
EO Sterilization Requirements Matrix (LIST 0101-EO) and the EO Sterilization Validation Kit Guide (GUIDE-EO), with a 10-stage road map, a worked example and a cross-reference to your own procedures.
Who it is for
Device makers validating a new EO process or product family, adopting a new product into an existing validation, or bringing an older validation and its annual reviews up to ISO 11135.
What you receive
An instant download of one zip file with a READ ME and two editions of the kit with the same content: one cites the procedure numbers of the ISO 13485 Manufacturing Plus system (for example SOP 7-035), the other the dual-standard system (for example SOP 7-035-C). Each edition has 1 guide, 1 requirements matrix, 3 procedures and 10 forms as editable Microsoft Word and Excel files, with a PDF copy of each.
Works with your quality system
The kit puts into action the Ethylene Oxide Sterilization Validation Procedure (SOP 7-035) and the Sterile Load Preparation and Release procedure (SOP 7-023) of the MDSAP-Ready ISO 13485 QMS Manufacturing Plus and MDSAP-Ready QMS Manufacturing Plus systems. If you use a different system, the guide's cross-reference table has a column for your own procedure numbers.
Your contract sterilizer runs the equipment and the cycles, and your contract laboratory runs the tests. The kit tells you what to ask each of them for and how to check what comes back.
Related guides
EO Sterilization Validation Under ISO 11135: A Step-by-Step Route
EO Half-Cycle Overkill Validation: Fractional Cycles, PCDs and Biological Indicators
Bioburden and Sterility Testing for EO Validation (ISO 11737-1 and -2)
Not sure this is the right package? Take the free QMS gap check: answer about 20 questions and see your gaps by clause, the procedures that close each one, and whether a complete system or individual procedures costs less.
Keep your system current: the A.P. Lyon Update Service
Standards and regulations change. With the Update Service, you don't have to track those changes yourself. Every quarter, subscribers get a standards update bulletin and any revised documents for their system, posted to a subscriber-only Update Library on this site. $149 per year per system, or $449 per year for consultants. Renews yearly; cancel anytime. See the plans and add one to your cart
