Cleanroom Qualification and Monitoring Kit | ISO 14644-1, 14644-2

$495.00Price
License
Single site: your organization
Consultant: use with your clients

11 procedures, forms and workbooks that take a medical device cleanroom or clean zone from its ISO 14644-1 classification test to routine ISO 14644-2 monitoring, with excursions handled and the classification kept current.


Quick facts


  • Product: Cleanroom Qualification and Monitoring Kit

  • Written to meet: ISO 14644-1:2015; ISO 14644-2:2015; ISO 14644-4:2022; ISO 13485:2016; 21 CFR Part 820; also references ISO 9001:2026

  • For: medical device makers and contract manufacturers that run cleanrooms or clean zones

  • Contents: 11 documents, including a sampling location and sample volume calculator workbook, a classification test report, a monitoring plan, a monitoring data and trend workbook that flags alert and action results, an excursion record, a classification schedule and requalification record, and a requirements matrix

  • Format: editable Microsoft Word and Excel files with PDF copies, in two editions (ISO 13485 and dual-standard procedure numbers), digital download

  • Price: $495 for a single-site license; $1,485 for a consultant license to use with clients


A cleanroom procedure says the room must be classified and monitored. It does not tell a team how many sampling locations Table A.1 needs for their room, how big each sample must be, what goes in the test report, what a monitoring plan must contain, or what to do when a count goes over the action level. This kit turns cleanroom classification and monitoring into a course of action. Every procedure step names who does it, which form to fill in and what comes next, with clause references kept in a separate column.


  • Cleanroom Classification Test Procedure (SOP 7-101-CRM) with the Sampling Location and Sample Volume Calculator (FORM 0101-CRM, Excel) and Cleanroom Classification Test Report (FORM 0102-CRM): the class designation, the number and position of sampling locations, sample volume and time, counter calibration, running the test, discarded counts and failures, pass or fail by location, and every item the test report must hold.

  • Cleanroom Monitoring Plan Procedure (SOP 7-102-CRM) with the Cleanroom Monitoring Plan (FORM 0103-CRM) and Monitoring Data and Trend Workbook (FORM 0104-CRM, Excel): the risk assessment, parameters, methods, locations in three dimensions, frequency, alert and action levels, pressure differential ranges, data recording and trend review.

  • Cleanroom Excursion and Requalification Procedure (SOP 7-103-CRM) with the Cleanroom Excursion Record (FORM 0105-CRM) and Classification Schedule and Requalification Record (FORM 0106-CRM): alert and action responses, investigation, product impact, reclassification after a significant change, the annual classification and how to justify a longer interval.

  • ISO 14644 Requirements Matrix (LIST 0101-CRM) and the Cleanroom Qualification and Monitoring Kit Guide (GUIDE-CRM), with an 8-stage road map, a worked example and a cross-reference to your own procedures.


Who it is for


Device makers preparing a first classification or an annual requalification, setting up or tightening cleanroom monitoring, or preparing for an audit or FDA inspection where environmental control records are checked.


What you receive


An instant download of one zip file with a READ ME and two editions of the kit with the same content: one cites the procedure numbers of the ISO 13485 Manufacturing Plus system (for example SOP 7-045), the other the dual-standard ISO 9001 + ISO 13485 system (for example SOP 7-045-C). Each edition has 1 guide, 1 requirements matrix, 3 procedures and 6 forms as editable Microsoft Word and Excel files, with a PDF copy of each.


Works with your quality system


The kit builds on the Cleanroom Design and Validation Procedure (SOP 7-045), Environmental Controls Procedure (SOP 7-013), Controlled Environment Cleaning Procedure (SOP 7-018) and Controlled Environment Gowning Procedure (SOP 6-005) of the MDSAP-Ready ISO 13485 QMS Manufacturing Plus and MDSAP-Ready QMS Manufacturing Plus systems and the Cleanroom Procedure Bundle, and does not replace them. If you use a different system, the guide's cross-reference table has a column for your own procedure numbers.


Related guides



Not sure this is the right package? Take the free QMS gap check: answer about 20 questions and see your gaps by clause, the procedures that close each one, and whether a complete system or individual procedures costs less.


Keep your system current: the A.P. Lyon Update Service


Standards and regulations change. With the Update Service, you don't have to track those changes yourself. Every quarter, subscribers get a standards update bulletin and any revised documents for their system, posted to a subscriber-only Update Library on this site. $149 per year per system, or $449 per year for consultants. Renews yearly; cancel anytime. See the plans and add one to your cart