The FDA Juice HACCP regulation, 21 CFR Part 120, was written after outbreaks of E. coli O157:H7 and Salmonella linked to unpasteurized apple cider and orange juice. At its center is one performance standard: your HACCP plan must include a process that achieves a 5-log reduction of the pertinent microorganism.


This guide explains what that means and how pasteurization, high pressure processing (HPP), ultraviolet (UV) light and citrus surface treatment meet it. It also covers how to validate the process, and how the 120.25 testing for citrus works.


What a 5-log reduction means


A 5-log reduction is a 100,000-fold reduction, so 99.999% of the target organisms are destroyed. If one milliliter of juice contained 100,000 cells of a pathogen before treatment, a 5-log process would leave no more than one cell.


Section 120.24(a) requires that the control measures in your HACCP plan "consistently produce, at a minimum, a 5-log (i.e., 10^5) decrease" in the pertinent microorganism. The reduction must last for at least as long as the shelf life of the product when it is stored under normal and moderate abuse conditions.


The pertinent microorganism


The pertinent microorganism is the most resistant microorganism of public health significance that is likely to occur in the juice. Depending on the juice and the process, the candidates are:


  • E. coli O157:H7 and other pathogenic E. coli

  • Salmonella species

  • Listeria monocytogenes

  • Cryptosporidium parvum, a parasite associated with apple cider


The pertinent microorganism can differ between processes. Listeria is more heat resistant than E. coli O157:H7 in some juices. Some pathogens are more pressure resistant than others in high-acid juice. Your validation must use the organism that is most resistant to your process.


Where the 5-log must happen


Section 120.24(b) requires that the 5-log treatment be applied directly to the juice, and that the reduction be accomplished within a single production facility. The one exception is citrus juice processors, who may apply treatments to the fruit surface. In that case, the process must begin after culling and cleaning, and it is subject to the E. coli testing in 120.25. For these processors, the definition of "culled" in 120.3(f) allows only undamaged, tree-picked fruit of USDA choice or higher quality, so dropped fruit cannot be used.


The 5-log process is a critical control point in the HACCP plan. Its critical limits are the measured parameters of the process (for example, time and temperature, pressure and hold time, or UV dose).


Pasteurization


Thermal pasteurization is the most widely used and best-understood 5-log process. For apple cider, FDA's Juice HACCP Hazards and Controls Guidance (First Edition, 2004) cites 160°F (71.1°C) for 6 seconds as an example process that delivers a 5-log reduction of E. coli O157:H7. Many processors run higher temperatures or longer holds for margin.


Typical critical limits are:


  • a minimum product temperature at the end of the holding tube

  • a minimum hold time, set by the flow rate and the holding tube length

  • a flow diversion device that diverts under-temperature juice automatically


Monitoring is usually continuous, using a temperature recorder, plus checks of the flow rate and the diversion valve at start-up. Verification includes daily records review and calibration of the indicating and recording thermometers against a reference.


High pressure processing (HPP)


HPP has become the standard process for cold-pressed juice. Bottled juice is placed in a water-filled vessel and held at very high pressure, commonly around 87,000 psi (600 MPa), for a period of time, often 1 to 3 minutes. The pressure inactivates vegetative pathogens without heat.


HPP works well, but it depends on the product:


  • pH, sugar content and juice type all affect lethality.

  • Pressure resistance differs between strains and organisms.

  • HPP does not reliably inactivate spores, so HPP juice must be kept refrigerated and given a validated shelf life.


Your HPP critical limits will usually be a minimum pressure, a minimum hold time and a maximum time between pressing and processing. These must be supported by a validation study on your juice, or one shown to be equivalent. Many brands use a tolling (contract) HPP provider. If you do, you remain responsible for the HACCP plan. Get the provider's cycle records for every batch and review them as CCP monitoring records.


UV treatment


FDA permits ultraviolet radiation for treating juice under 21 CFR 179.39. UV systems pump juice in a thin film or turbulent flow past UV lamps. UV is used mainly for apple cider by small orchards, because the equipment costs much less than a pasteurizer or HPP system.


UV has an important limitation. Juice absorbs UV light, so the delivered dose depends on:


  • juice color and clarity

  • the amount of suspended solids

  • flow rate

  • lamp intensity, which falls as the lamps age


Validation must cover the range of juice your system will treat. The critical limits typically include:


  • minimum UV dose, or minimum lamp intensity at a given flow rate

  • maximum flow rate

  • maximum juice absorbance (or a minimum transmittance)


Monitoring includes lamp output sensors and flow rate. Lamp replacement and quartz sleeve cleaning become verification activities.


Citrus surface treatment


Citrus fruit has an intact peel, and pathogens on whole fruit are mostly on its surface. For this reason, 120.24(b) allows citrus processors to achieve the 5-log reduction by treating the fruit surface rather than the juice. A typical process includes:


  1. Culling damaged and dropped fruit.

  2. Cleaning, such as brushing and washing with an approved sanitizer at a set concentration and contact time.

  3. A hot water treatment or a defined sanitizing step.

  4. Strict controls on the extraction step, so the peel does not contaminate the juice.


The 120.25 E. coli testing requirement


Because surface treatment is less direct than treating the juice, 120.25 requires citrus processors who use it to test the juice for generic E. coli as process verification. In summary:


  • Take one 20 mL sample (two 10 mL subsamples) for each 1,000 gallons produced each production day. If you produce less than 1,000 gallons per day, take one sample each day you produce, and at least every 5 working days.

  • Test using the method in 120.25 or an equivalent method.

  • If one sample is positive, review the monitoring records for the control measures and correct any deficiencies.

  • If two samples in a series of seven consecutive samples are positive, you must do four things:

    1. Use an alternative process that achieves the 5-log reduction after juice extraction, until the cause is corrected and the surface treatment is shown to be effective again.

    2. Review the monitoring records.

    3. Correct any deficiencies, or validate that the process is effective.

    4. Take corrective action under 120.10.


Validating your 5-log process


Validation shows that your process, as you actually run it, achieves the 5-log reduction for your juice. Typical evidence includes:


  • Scientific basis: published studies, FDA guidance, or a process authority's evaluation that the process parameters deliver a 5-log reduction of the pertinent organism in this type of juice.

  • Challenge study (for HPP, UV and novel processes): the juice is inoculated with the target organism or a surrogate, processed at the critical limits, and tested to show the reduction achieved.

  • In-plant data: records showing the equipment consistently reaches the critical limits, including temperature distribution, actual hold times, and lamp output under real conditions.


Validation must be repeated when anything that affects lethality changes. Examples include a new juice blend with a different pH or more pulp, new equipment, or a new pressure cycle.


Choosing a process for your business


The right 5-log process depends on the juice, the volume and the market more than on the technology.


  • Small orchard cider sold locally: UV or a small batch or HTST pasteurizer. UV keeps a fresh taste but needs clear juice and careful lamp maintenance.

  • Cold-pressed juice sold through stores: HPP, usually through a contract HPP provider until volume justifies owning a machine. Expect a refrigerated shelf life set by your own validation and shelf-life testing.

  • Fresh orange juice at a citrus packer: surface treatment of the fruit, with 120.25 E. coli testing as process verification.

  • Shelf-stable juice: a thermal process that also makes the juice shelf-stable, or a process under the acidified food rules, which brings the 120.24(a) exemption from the 5-log requirement.


Common inspection findings for juice processors


FDA investigators look first at the 5-log CCP. The problems they cite most often include:


  • no validation, or a validation study for a different juice, pH or bottle size than the one being produced

  • HPP cycle records never received from the contract provider, or received but not reviewed

  • missed 120.25 E. coli samples for citrus surface treatment

  • thermometers and pressure gauges with no calibration records

  • a HACCP plan with no annual reassessment under 120.11

  • no trained individual under 120.13, or no record of that person's training


For more on what investigators write up, see our guide to FDA 483 observations under 21 CFR Part 120.


The rest of the Juice HACCP plan


The 5-log process is only one CCP. A complete juice HACCP program also covers:


  • Sanitation control procedures under 120.6, with daily monitoring of the eight key sanitation conditions.

  • A written hazard analysis under 120.7. It addresses chemical hazards such as patulin in apple juice (50 ppb action level), inorganic arsenic in apple juice (10 ppb action level), lead and pesticides. It also addresses physical hazards such as glass, and undeclared allergens in blends.

  • Corrective action plans under 120.10.

  • Verification and an annual validation of the HACCP plan under 120.11.

  • Records under 120.12.

  • A trained individual under 120.13, who develops the plan, reviews records and validates the plan.


Get a complete juice HACCP program


Our Juice HACCP Program includes:


  • SOP 7-104-JU 5-Log Pathogen Reduction: Process Selection and Validation

  • SOP 7-105-JU Citrus Surface Treatment and E. coli Process Verification

  • four worked HACCP plans: HPP cold-pressed juice, pasteurized cider, citrus surface treatment and UV cider

  • HPP, pasteurization, UV and citrus treatment logs, and an E. coli verification testing record


In total, the program contains 50 editable documents.



This guide is general information, not legal advice. Your 5-log process must be validated for your juice and equipment. Consult a process authority where needed.




Not sure where your quality system stands? Take the free QMS gap check: about 20 questions, an instant report of your gaps by clause, and the procedures that close each one.


Just getting started? The free Startup Quality Plan shows which procedures you need now, which can wait, and how long they take to put in place.

Comments


bottom of page